Shear bond strength of resin-modified glass ionomer cement bound to mineral trioxide aggregate after various disinfection protocols


Yanık D., ER K., KUŞTARCI A.

Australian Endodontic Journal, cilt.49, sa.1, ss.159-164, 2023 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 49 Sayı: 1
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1111/aej.12641
  • Dergi Adı: Australian Endodontic Journal
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, EMBASE, MEDLINE
  • Sayfa Sayıları: ss.159-164
  • Anahtar Kelimeler: cavity disinfection, laser, mineral trioxide aggregate, ozone, shear bond strength
  • Süleyman Demirel Üniversitesi Adresli: Hayır

Özet

This study compared the effects of 3 different cavity disinfection protocols (CDP) on the shear bond strength (SBS) of resin-modified glass ionomer cement (RM-GIC) to mineral trioxide aggregate (MTA). One hundred eighty standard holes were prepared and filled with MTA. They then divided into 3 main groups based on the chosen time intervals (15 min, 24 h, and 72 h). Main groups were divided into 3 subgroups based on the CDP [chlorhexidine gluconate (CHX), ozone, laser, and control]. RM-GIC was applied on MTA after CDP for all groups. A universal testing device was then used for test and the data was statistically analysed. CHX showed significantly lower SBS values except ozone and laser than the control (p < 0.05). There were no statistically significant differences among the time intervals. As a result, CHX decreased the bond strength between the MTA and RM-GIC while ozone and laser had no negative effect.